[ TVSHELL FILE RT90 $V00010000 ] $Ref = "A demonstration composite test" [ --------------------------------------------------------------------------- ] [ Hardware : RT90 ] [ Software : RT90 SOFTWARE ] [ Version : V1.01p 23/9/97 ] [ Written on : 10:10:23, Monday, 1st December 1997 ] [ --------------------------------------------------------------------------- ] {:----} {.1} 1 [-] "Batch definition" A demonstration composite test {#BCH} {:----} {.5} CONDITION LIST {:----} C1 Part Number = No part number {:----} C2 Device Type = No Device Type {:----} C4 Operator = No operator {:----} C5 Batch = No batch {:----} C6 Lot = No lot {:----} C7 Sample Plan = No sample plan {:----} C20 Device routing = None specified {:----} {.10} * {:----} {.2} RESULT LIST {:----} R1 Last test run at = 10:10:15, Monday, 1st December 1997 {:----} R2 Tester Name = RT90 {:----} R3 Software Name = RT90 SOFTWARE {:----} R4 Version Name = V1.01p 23/9/97 {:----} R5 File reference = A demonstration composite test {:----} {.10} * {:----} {.8} DATALOG True [{#0}] {:----} {.9} PRINT True [{#0}] {:----} {.17} ----------------------------------------------------------------------------- {:----} {.1} 2 [-] "Measure VOperate" {#VRM} {:----} {.5} CONDITION LIST {:----} C121 Device coil format = As monostable A+ {#0} {:----} C101 Device contact format = 2PCO (Sets 1,2) {#4} {:----} C102 Contacts to test = C,C,X,X,X,X,X,X {:----} C201 # Voltage default = 5.000 V {:----} C301 # Current default = 0.000 mA {:----} C401 # RCoil default = 0.000 kR {:----} C501 # TStable default = 0.000 ms {:----} C124 Device coil suppression = Network #1 {#1} {:----} C510 Settling time = 0.500 ms {:----} C211 Saturate voltage = 4.000 V {:----} C511 Saturate time = 100.000 ms {:----} C310 Current to apply = 100.000 mA {:----} C701 Operate segment mode = Keep drive and exit {#2} {:----} C222 Operate ramp start voltage = 0.500 V {:----} C223 Operate ramp step voltage = 0.005 V {:----} C224 Operate Min must operate [ /225] = 2.000 V {:----} C225 Operate Max must operate [224/ ] = 5.000 V {:----} C226 Operate Min must release [ /211] = 0.000 V {:----} C227 Operate Max must release [ /211] = 3.750 V {:----} C228 Operate Max unstable region [ /211] = 1.500 V {:----} C702 Release segment mode = Skip segment {#1} {:----} C242 Release ramp start voltage = 5.000 V {:----} C243 Release ramp step voltage = 0.050 V {:----} C244 Release Min must release [ /245] = 0.000 V {:----} C245 Release Max must release [244/211] = 3.000 V {:----} C246 Release Min must operate [ /211] = 0.500 V {:----} C247 Release Max must operate [ /211] = 4.000 V {:----} C248 Release Max unstable region [ /211] = 1.500 V {:----} {.10} * {:----} {.3} RESULT SUMMARY {:----} {.4} TOTALS THIS STEP 0% Batch[P:0,T:0,F:0] Seq[P:0,T:0,F:0] {:----} {.2} RESULT LIST {:----} R1 Test status = Test OK {#0} {:----} R110 Opr: just operated [224/225]< = 0.100 V {:----} R111 Opr: just released [226/227] = 0.100 V {:----} R112 Opr: unstable region [ /228] = 5.000 V {:----} R114 Rel: just released [244/245] = 0.100 V {:----} R115 Rel: just operated [246/247] = 0.100 V {:----} R116 Rel: unstable region [ /248] = 5.000 V {:----} {.10} * {:----} {.8} DATALOG True [{#0}] {:----} {.9} PRINT True [{#0}] {:----} {.12} HANDLER BIN Fail:1, Pass:0 {#1}{%0} {:----} {.7} JUMP False [{#3}] to ELSE {%-1}{!-2} {:----} {.17} ----------------------------------------------------------------------------- {:----} {.1} 3 [-] "Measure CRNO" {#CTR} {:----} {.5} CONDITION LIST {:----} C121 Device coil format = VI Changes only {#9} {:----} C101 Device contact format = 2PCO (Sets 1,2) {#4} {:----} C102 Contacts to test = C,C,X,X,X,X,X,X {:----} C201 # Voltage default = 0.000 V {:----} C301 # Current default = 0.000 mA {:----} C402 # RContact default = 0.0000 R {:----} C401 # RCoil default = 0.000 kR {:----} C501 # TStable default = 0.000 ms {:----} C124 Device coil suppression = Network #1 {#1} {:----} C103 Contact side to measure = Normally open {#0} {:----} C212 VClamp = 50 mV {:----} C104 Contact load = CA0 (as gen and clamp) {#0} {:----} C210 Voltage to apply = 0.080 V [MeasureVOperate.R110 * 0.8] {:----} C310 Current to apply = 100.000 mA {:----} C510 Settling time = 100.000 ms {:----} C410 CR Measurement range = 1R {#0} {:----} C411 CR measurement precision = 80ms 25Hz {#0} {:----} C412 Min RContact pass limit [ /413] = 0.0000 R {:----} C413 Max RContact pass limit [412/ ] = 100.00 mR {:----} {.10} * {:----} {.3} RESULT SUMMARY {:----} {.4} TOTALS THIS STEP 0% Batch[P:0,T:0,F:0] Seq[P:0,T:0,F:0] {:----} {.2} RESULT LIST {:----} R1 Test status = Test OK {#0} {:----} R499 CR: Max this test [412/413] = 0.0000 R {:----} R491 CR: Contact #1 [412/413] = 0.0000 R {:----} R492 CR: Contact #2 [412/413] = 0.0000 R {:----} R493 CR: Contact #3 [412/413] = 0.0000 R {:----} R494 CR: Contact #4 [412/413] = 0.0000 R {:----} R495 CR: Contact #5 [412/413] = 0.0000 R {:----} R496 CR: Contact #6 [412/413] = 0.0000 R {:----} {.10} * {:----} {.8} DATALOG True [{#0}] {:----} {.9} PRINT True [{#0}] {:----} {.12} HANDLER BIN Fail:1, Pass:0 {#1}{%0} {:----} {.7} JUMP False [{#3}] to ELSE {%-1}{!-2} {:----} {.17} ----------------------------------------------------------------------------- {:----} {.1} 4 [-] "Measure VRelease" {#VRM} {:----} {.5} CONDITION LIST {:----} C121 Device coil format = As monostable A+ {#0} {:----} C101 Device contact format = 2PCO (Sets 1,2) {#4} {:----} C102 Contacts to test = C,C,X,X,X,X,X,X {:----} C201 # Voltage default = 5.000 V {:----} C301 # Current default = 0.000 mA {:----} C401 # RCoil default = 0.000 kR {:----} C501 # TStable default = 0.000 ms {:----} C124 Device coil suppression = Network #1 {#1} {:----} C510 Settling time = 0.500 ms {:----} C211 Saturate voltage = 5.000 V {:----} C511 Saturate time = 100.000 ms {:----} C310 Current to apply = 100.000 mA {:----} C701 Operate segment mode = Skip segment {#1} {:----} C222 Operate ramp start voltage = 0.500 V {:----} C223 Operate ramp step voltage = 0.050 V {:----} C224 Operate Min must operate [ /225] = 2.000 V {:----} C225 Operate Max must operate [224/ ] = 5.000 V {:----} C226 Operate Min must release [ /211] = 0.000 V {:----} C227 Operate Max must release [ /211] = 3.750 V {:----} C228 Operate Max unstable region [ /211] = 1.500 V {:----} C702 Release segment mode = Keep drive and exit {#2} {:----} C242 Release ramp start voltage = 5.000 V {:----} C243 Release ramp step voltage = 0.005 V {:----} C244 Release Min must release [ /245] = 0.000 V {:----} C245 Release Max must release [244/211] = 3.000 V {:----} C246 Release Min must operate [ /211] = 0.500 V {:----} C247 Release Max must operate [ /211] = 5.000 V {:----} C248 Release Max unstable region [ /211] = 1.500 V {:----} {.10} * {:----} {.3} RESULT SUMMARY {:----} {.4} TOTALS THIS STEP 0% Batch[P:0,T:0,F:0] Seq[P:0,T:0,F:0] {:----} {.2} RESULT LIST {:----} R1 Test status = Test OK {#0} {:----} R110 Opr: just operated [224/225] = 0.100 V {:----} R111 Opr: just released [226/227] = 0.100 V {:----} R112 Opr: unstable region [ /228] = 5.000 V {:----} R114 Rel: just released [244/245] = 0.100 V {:----} R115 Rel: just operated [246/247] = 0.100 V {:----} R116 Rel: unstable region [ /248] = 5.000 V {:----} {.10} * {:----} {.8} DATALOG True [{#0}] {:----} {.9} PRINT True [{#0}] {:----} {.12} HANDLER BIN Fail:1, Pass:0 {#1}{%0} {:----} {.7} JUMP False [{#3}] to ELSE {%-1}{!-2} {:----} {.17} ----------------------------------------------------------------------------- {:----} {.1} 5 [-] "Measure CRNC" {#CTR} {:----} {.5} CONDITION LIST {:----} C121 Device coil format = VI Changes only {#9} {:----} C101 Device contact format = 2PCO (Sets 1,2) {#4} {:----} C102 Contacts to test = C,C,X,X,X,X,X,X {:----} C201 # Voltage default = 0.000 V {:----} C301 # Current default = 0.000 mA {:----} C402 # RContact default = 0.0000 R {:----} C401 # RCoil default = 0.000 kR {:----} C501 # TStable default = 0.000 ms {:----} C124 Device coil suppression = Network #1 {#1} {:----} C103 Contact side to measure = Normally closed {#1} {:----} C212 VClamp = 50 mV {:----} C104 Contact load = CA0 (as gen and clamp) {#0} {:----} C210 Voltage to apply = 0.180 V [MeasureVRelease.R114 * 1.8] {:----} C310 Current to apply = 100.000 mA {:----} C510 Settling time = 15.000 ms {:----} C410 CR Measurement range = 1R {#0} {:----} C411 CR measurement precision = 80ms 25Hz {#0} {:----} C412 Min RContact pass limit [ /413] = 0.0000 R {:----} C413 Max RContact pass limit [412/ ] = 100.00 mR {:----} {.10} * {:----} {.3} RESULT SUMMARY {:----} {.4} TOTALS THIS STEP 0% Batch[P:0,T:0,F:0] Seq[P:0,T:0,F:0] {:----} {.2} RESULT LIST {:----} R1 Test status = Test OK {#0} {:----} R499 CR: Max this test [412/413] = 0.0000 R {:----} R491 CR: Contact #1 [412/413] = 0.0000 R {:----} R492 CR: Contact #2 [412/413] = 0.0000 R {:----} R493 CR: Contact #3 [412/413] = 0.0000 R {:----} R494 CR: Contact #4 [412/413] = 0.0000 R {:----} R495 CR: Contact #5 [412/413] = 0.0000 R {:----} R496 CR: Contact #6 [412/413] = 0.0000 R {:----} {.10} * {:----} {.8} DATALOG True [{#0}] {:----} {.9} PRINT True [{#0}] {:----} {.12} HANDLER BIN Fail:1, Pass:0 {#1}{%0} {:----} {.7} JUMP False [{#3}] to ELSE {%-1}{!-2} {:----} {.17} ----------------------------------------------------------------------------- {.Overview_Start} {.Overview_End}